LIST OF FIGURES
1-159. Graphs showing:
- Display of ordinary least-squares regression equation derived for sodium
 - Alkalinity, whole-water recoverable, (electrometric titration) data from
the National Water Quality Laboratory
 - Aluminum, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
 - Aluminum, dissolved, (inductively coupled plasma-mass spectrometry) data
from the National Water Quality Laboratory
 - Aluminum, whole-water recoverable, (direct current plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
 - Antimony, dissolved, (hydride generation-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
 - Antimony, dissolved, (inductively coupled plasma-mass spectrometry) data
from the National Water Quality Laboratory
 - Arsenic, dissolved, (hydride generation-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
 - Arsenic, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry, U.S. Environmental Protection Agency) data from the National
Water Quality Laboratory
 - Arsenic, whole-water recoverable, (hydride generation-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
 - Barium, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
 - Barium, dissolved, (inductively coupled plasma-mass spectrometry) data
from the National Water Quality Laboratory
 - Beryllium, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
 - Beryllium, dissolved, (inductively coupled plasma-mass spectrometry) data
from the National Water Quality Laboratory
 - Boron, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
 - Boron, whole-water recoverable, (direct current plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
 - Cadmium, dissolved, (graphite furnace-atomic absorption spectrophotometry)
 data from the National Water Quality Laboratory
 - Cadmium, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
 - Cadmium, dissolved, (inductively coupled plasma-mass spectrometry) data
from the National Water Quality Laboratory
 - Cadmium, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
 - Calcium, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
 - Chloride, dissolved, (ion chromatography) data from the National Water
Quality Laboratory
 - Chloride, dissolved, (ion chromatography, low level) data from the
National Water Quality Laboratory
 - Chromium, dissolved, (graphite furnace-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
 - Chromium, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
 - Chromium, dissolved, (inductively coupled plasma-mass spectrometry) data
from the National Water Quality Laboratory
 - Chromium, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
 - Cobalt, dissolved, (graphite furnace-atomic absorption spectrophotometry)
 data from the National Water Quality Laboratory
 - Cobalt, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
 - Cobalt, dissolved, (inductively coupled plasma-mass spectrometry) data
from the National Water Quality Laboratory
 - Cobalt, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
 - Copper, dissolved, (graphite furnace-atomic absorption spectrophotometry)
 data from the National Water Quality Laboratory
 - Copper, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
 - Copper, dissolved, (inductively coupled plasma-mass spectrometry) data
from the National Water Quality Laboratory
 - Copper, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
 - Dissolved solids, dissolved, (gravimetric) data from the National Water
Quality Laboratory
 - Fluoride, dissolved, (ion chromatography, low level) data from the
National Water Quality Laboratory
 - Fluoride, dissolved, (ion-selective electrode) data from the National
Water Quality Laboratory
 - Iron, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
 - Iron, whole-water recoverable, (flame-atomic absorption spectrophotometry)
 data from the National Water Quality Laboratory
 - Lead, dissolved, (graphite furnace-atomic absorption spectrophotometry)
 data from the National Water Quality Laboratory
 - Lead, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
 - Lead, dissolved, (inductively coupled plasma-mass spectrometry) data from
the National Water Quality Laboratory
 - Lead, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
 - Lithium, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
 - Lithium, whole-water recoverable, (flame-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
 - Magnesium, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
 - Manganese, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
 - Manganese, dissolved, (inductively coupled plasma-mass spectrometry) data
from the National Water Quality Laboratory
 - Manganese, whole-water recoverable, (flame-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
 - Mercury, dissolved, (cold vapor-atomic absorption spectrophotometry) data
from the National Water Quality Laboratory
 - Mercury, whole-water recoverable, (cold vapor-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
 - Molybdenum, dissolved, (graphite furnace-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
 - Molybdenum, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
 - Molybdenum, dissolved, (inductively coupled plasma-mass spectrometry)
 data from the National Water Quality Laboratory
 - Molybdenum, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
 - Nickel, dissolved, (graphite furnace-atomic absorption spectrophotometry)
 data from the National Water Quality Laboratory
 - Nickel, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
 - Nickel, dissolved, (inductively coupled plasma-mass spectrometry) data
from the National Water Quality Laboratory
 - Nickel, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
 - Potassium, dissolved, (flame-atomic absorption spectrophotometry) data
from the National Water Quality Laboratory
 - Potassium, dissolved, (flame-atomic absorption spectrophotometry, low
level) data from the National Water Quality Laboratory
 - Selenium, dissolved, (hydride generation-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
 - Selenium, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry, U.S. Environmental Protection Agency) data from the National
Water Quality Laboratory
 - Selenium, whole-water recoverable, (hydride generation-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
 - Silica, dissolved, (colorimetric) data from the National Water Quality
Laboratory
 - Silica, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
 - Silver, dissolved, (graphite furnace-atomic absorption spectrophotometry)
 data from the National Water Quality Laboratory
 - Silver, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
 - Silver, dissolved, (inductively coupled plasma-mass spectrometry) data
from the National Water Quality Laboratory
 - Silver, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
 - Sodium, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
 - Specific conductance, whole-water recoverable, (electrometric, low level)
 data from the National Water Quality Laboratory
 - Strontium, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
 - Sulfate, dissolved, (ion chromatography) data from the National Water
Quality Laboratory
 - Vanadium, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
 - Zinc, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
 - Zinc, dissolved, (inductively coupled plasma-mass spectrometry) data from
the National Water Quality Laboratory
 - Zinc, whole-water recoverable, (flame-atomic absorption spectrophotometry)
 data from the National Water Quality Laboratory
 - Ammonia as nitrogen, dissolved, (colorimetric) data from the National
Water Quality Laboratory
 - Ammonia as nitrogen, dissolved, (colorimetric, low level) data from the
National Water Quality Laboratory
 - Ammonia as nitrogen, dissolved, (U.S. Environmental Protection Agency)
 data from the National Water Quality Laboratory
 - Ammonia plus organic nitrogen as nitrogen, dissolved, (micro-Kjeldahl
digestion, automated segmented flow, colorimetric) data from the National Water
Quality Laboratory
 - Ammonia plus organic nitrogen as nitrogen, dissolved, (U.S. Environmental
Protection Agency) data from the National Water Quality Laboratory
 - Ammonia plus organic nitrogen as nitrogen, whole-water recoverable,
(micro-Kjeldahl digestion, automated segmented flow, colorimetric) data from the
National Water Quality Laboratory
 - Ammonia plus organic nitrogen as nitrogen, whole-water recoverable, (U.S.
Environmental Protection Agency) data from the National Water Quality Laboratory
 - Nitrate plus nitrite as nitrogen, dissolved, (colorimetric) data from the
National Water Quality Laboratory
 - Nitrate plus nitrite as nitrogen, dissolved, (colorimetric, low level)
 data from the National Water Quality Laboratory
 - Orthophosphate as phosphorus, dissolved, (colorimetric) data from the
National Water Quality Laboratory
 - Orthophosphate as phosphorus, dissolved, (colorimetric, low level) data
from the National Water Quality Laboratory
 - Phosphorus, dissolved, (micro-Kjeldahl digestion, automated segmented
flow, colorimetric) data from the National Water Quality Laboratory
 - Phosphorus, dissolved, (colorimetric, low level) data from the National
Water Quality Laboratory
 - Phosphorus, dissolved, (U.S. Environmental Protection Agency) data from
the National Water Quality Laboratory
 - Phosphorus, whole-water recoverable, (micro-Kjeldahl digestion, automated
segmented flow, colorimetric) data from the National Water Quality Laboratory
 - Phosphorus, whole-water recoverable, (colorimetric, low level) data from
the National Water Quality Laboratory
 - Phosphorus, whole-water recoverable, (U.S. Environmental Protection
Agency) data from the National Water Quality Laboratory
 - Alkalinity, whole-water recoverable, (electrometric titration) data from
the Quality of Water Service Unit laboratory
 - Aluminum, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
 - Aluminum, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry, U.S. Environmental Protection Agency) data from the Quality
of Water Service Unit laboratory
 - Aluminum, whole-water recoverable, (inductively coupled plasma-atomic
emission spectrometry, trace) data from the Quality of Water Service Unit
laboratory
 - Arsenic, dissolved, (graphite furnace-atomic absorption
spectrophotometry) data from the Quality of Water Service Unit laboratory
 - Arsenic, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the Quality of Water Service Unit laboratory
 - Barium, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
 - Barium, whole-water recoverable, (inductively coupled plasma-atomic
emission spectrometry, trace) data from the Quality of Water Service Unit
laboratory
 - Beryllium, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
 - Beryllium, whole-water recoverable, (inductively coupled plasma-atomic
emission spectrometry, trace) data from the Quality of Water Service Unit
laboratory
 - Boron, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
 - Cadmium, dissolved, (graphite furnace-atomic absorption
spectrophotometry) data from the Quality of Water Service Unit laboratory
 - Cadmium, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
 - Cadmium, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the Quality of Water Service Unit laboratory
 - Cadmium, whole-water recoverable, (inductively coupled plasma-atomic
emission spectrometry, trace) data from the Quality of Water Service Unit
laboratory
 - Calcium, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the Quality of Water Service Unit laboratory
 - Calcium, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
 - Chloride, dissolved, (ion chromatography) data from the Quality of Water
Service Unit laboratory
 - Chromium, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
 - Chromium, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the Quality of Water Service Unit laboratory
 - Chromium, whole-water recoverable, (inductively coupled plasma-atomic
emission spectrometry, trace) data from the Quality of Water Service Unit
laboratory
 - Cobalt, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
 - Copper, dissolved, (graphite furnace-atomic absorption spectrophotometry)
 data from the Quality of Water Service Unit laboratory
 - Copper, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
 - Copper, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the Quality of Water Service Unit laboratory
 - Copper, whole-water recoverable, (inductively coupled plasma-atomic
emission spectrometry, trace) data from the Quality of Water Service Unit
laboratory
 - Dissolved solids, dissolved, (gravimetric) data from the Quality of
Water Service Unit laboratory
 - Fluoride, dissolved, (ion-selective electrode) data from the Quality of
Water Service Unit laboratory
 - Iron, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
 - Iron, whole-water recoverable, (inductively coupled plasma-atomic
emission spectrometry, trace) data from the Quality of Water Service Unit
laboratory
 - Lead, dissolved, (graphite furnace-atomic absorption spectrophotometry)
 data from the Quality of Water Service Unit laboratory
 - Lead, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
 - Lead, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the Quality of Water Service Unit laboratory
 - Lead, whole-water recoverable, (inductively coupled plasma-atomic
emission spectrometry, trace) data from the Quality of Water Service Unit
laboratory
 - Magnesium, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the Quality of Water Service Unit laboratory
 - Magnesium, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
 - Manganese, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
 - Manganese, whole-water recoverable, (inductively coupled plasma-atomic
emission spectrometry, trace) data from the Quality of Water Service Unit
laboratory
 - Mercury, whole-water recoverable, (cold vapor-atomic absorption
spectrophotometry) data from the Quality of Water Service Unit laboratory
 - Molybdenum, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
 - Nickel, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
 - Nickel, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the Quality of Water Service Unit laboratory
 - Nickel, whole-water recoverable, (inductively coupled plasma-atomic
emission spectrometry, trace) data from the Quality of Water Service Unit
laboratory
 - Potassium, dissolved, (flame-atomic absorption spectrophotometry) data
from the Quality of Water Service Unit laboratory
 - Selenium, dissolved, (graphite furnace-atomic absorption
spectrophotometry) data from the Quality of Water Service Unit laboratory
 - Selenium, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the Quality of Water Service Unit laboratory
 - Silica, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the Quality of Water Service Unit laboratory
 - Silica, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
 - Silver, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
 - Sodium, dissolved, (flame-atomic absorption spectrophotometry) data from
the Quality of Water Service Unit laboratory
 - Strontium, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
 - Strontium, whole-water recoverable, (inductively coupled plasma-atomic
emission spectrometry, trace) data from the Quality of Water Service Unit
laboratory
 - Sulfate, dissolved, (ion chromatography) data from the Quality of Water
Service Unit laboratory
 - Vanadium, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
 - Zinc, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
 - Zinc, whole-water recoverable, (inductively coupled plasma-atomic
emission spectrometry, trace) data from the Quality of Water Service Unit
laboratory
 - Ammonia as nitrogen, dissolved, data from the Quality of Water Service
Unit laboratory
 - Ammonia plus organic nitrogen as nitrogen, dissolved, data from the
Quality of Water Service Unit laboratory
 - Ammonia plus organic nitrogen as nitrogen, whole-water recoverable, data
from the Quality of Water Service Unit laboratory
 - Nitrate plus nitrite as nitrogen, dissolved, data from the Quality of
Water Service Unit laboratory
 - Orthophosphate as phosphorus, dissolved, data from the Quality of Water
Service Unit laboratory
 - Phosphorus, dissolved, data from the Quality of Water Service Unit
laboratory
 - Phosphorus, whole-water recoverable, data from the Quality of Water
Service Unit laboratory
 
Back to Top
Back to Report