An html version of the abstract is shown below. This report is available as a .21 MB pdf file WRI-99-4184
This
report describes the results of the first 3 years of an ongoing study of
sediment laboratories used by the U.S. Geological Survey (USGS).
The sediment laboratories currently in operation constitute the entire
USGS national laboratory system for sediment analyses.
As with all environmental data, physical sediment data can be expected to
contain a certain amount of difference, whether the difference resulted from the
collecting, transporting, or analyzing of the sample. Because it is important to
know how each laboratory is performing, the USGS initiated the Sediment
Laboratory Quality-Assurance (SLQA) project in August 1996.
From August 1996 through June 1998, five studies were made, the results
of which are the basis of this report.
The
focus of the project is on quantitative analyses done on water-sediment mixtures
to derive suspended-sediment concentrations, sediment-mass determinations, and
sand/fine separations. For the purpose of this report, all mass determinations
are net valuesthe tare weight of the container is excluded.
The fine-size material is defined as particles sieved to a size of
less than 62 micrometers (mm)
and sand-size material is
defined as particles sieved to a size of between 63 and 125 mm.
Also, in this report, size class 1 is defined as samples containing 50 to
100 milligrams (mg) of fine-size material, size class 2 is defined as samples
containing 101 to 300 mg of fine-size material, and size class 3 is defined as
samples containing 2,200 to 3,200 mg of fine-size material.
In studies 96-1 through 98-1, the amount of sand added to each sample
ranged from 9 to 28 percent of the mass of fine-size material in each size
class.
Analytical results from all sediment quality-control samples are compiled and statistically summarized by the USGS, Branch of Quality Systems , both on an intra- and interlaboratory basis. When evaluating these data, the reader needs to keep in mind that every measurement has an error component associated with it. It is premature to use the data from the first five SLQA studies to judge any of the laboratories as performing in an unacceptable manner. There were, however, some notable differences in the results for the 12 laboratories that participated in the five SLQA studies. For example, the overall median percent difference for suspended-sediment concentration on an individual laboratory basis ranged from 18.04 to 0.33 percent. Five of the 12 laboratories had an overall median percent difference for suspended-sediment concentration of 2.02 to 0.33 percent. There was less variability in the median difference for the measured fine-size material mass. The overall median percent difference for fine-size material mass ranged from 10.11 to 4.27 percent. Except for one laboratory, the median difference for fine-size material mass was within a fairly narrow range of 6.76 to 4.27 percent. The median percent difference for sand-size material mass differed among laboratories more than any other physical sediment property measured in the study. The overall median percent difference for the sand-size material mass ranged from 1.49 percent to 26.39 percent. Five of the nine laboratories that do sand/fine separations had overall median percent differences that ranged from 1.49 to 2.98 percent for sand-size material mass. Careful review of the data reveals that certain laboratories consistently produced data within statistical control limits for some or all of the physical sediment properties measured in this study, whereas other laboratories occasionally produced data that exceeded the control limits.
Abstract
Introduction
Experimental Design of the Sediment Laboratory Quality-Assurance Project
Sample Preparation
Interlaboratory Comparisons
Intralaboratory Assessments
Laboratory Participation
Analysis and Interpretation of Project Data
Comparison of the 1996-98 Sediment Laboratory Quality-Assurance Results with the
Results from Pilot Studies in Previous Years
Control Charts of the 1996-98 Sediment Laboratory Quality-Assurance Results
Recently implemented and proposed Plans
Summary
References
If you have Adobe Acrobat Reader installed on your computer, you may view and/or print the PDF version of this report. If you do not have Acrobat Reader, you may download it here.
pdf file of the report: WRI 99-4184
USGS | Water | Biology | Geology | Mapping | WRI Pubs | Water Related Pubs |